We use cookies to try and give you a better experience in Freshdesk. logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. *, We appreciate your effort and will try to fix the article. Start by opening yourWiFisettings and then connecting to the network that starts with "AP" - this is theWiFilogger's local network which allows you to link it to the home network. WiFi datalogger firmware is out of date I need a better guide to enable me to connect via an Apple Mac and PC. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Simple connectivity has your Solis solar system online in just a few steps delivering ongoing comprehensive data analysis and fault finding anytime, anywhere. Then plug the Wifi Data Logger into the port and be sure to secure it by tightening the black connector. Comment * document.getElementById("comment").setAttribute("id","afdcdc86cefb6e10bf27816a9d02011c");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals) 2. Copyright@2020 Ginlong Technologies All rights reserved, If the network is not appearing, press and hold the Reset button down for 10 seconds until both NET and COM lights start to flash simultaneously, This network must be 2.4GHz as 5GHz networks are not supported. The consent submitted will only be used for data processing originating from this website. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. Solis WIFI and LAN Data Logger Datasheet.pdf, Solis WIFI Logger Installation Manual v2.4 (1).pdf. When configured correctly (see below), Solis invertors will send data about their performance every 5 minutes to code waiting to receive the data. SolisCloud Step 2: If it is a new data logger, please configure it first, then click the " Willi configure". No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. Or directly download from APP Store or Google Play Store by searching "SolisCloud". If there are symbols in the password, it must be changed or the logger will not connect to it. Solis Data Logger Server Information - firewall exceptions Modified on Fri, 09 Dec 2022 at 02:15 PM When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. Solis Monitoring. Connect the WIFI stick by attaching it to the green plug on the bottom of all Solis inverters. When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. Sorry we couldn't be helpful. solis S4-GPRS GPRS Stick Datalogger Installation Guide, solis SOL-DLS-W Data Logger Wifi Stick User Guide, DAIKIN BRP069B45 WiFi Adapter Installation Guide, ideal lux 306445 Clara PL Square 4000K Ceiling Light Owners Manual, Microderm GLO NVD-MGM-GR1802 Blackhead Remover Pore Vacuum User Guide, AVALON A3F Bottom Loading Water Cooler Water Dispenser User Manual, boAt Wave Lynk Voice Premium Smartwatch User Manual, motorline RAP50 Microwave Presence Sensor User Manual, kbice FDFM1JA01 Self Dispensing Nugget Ice Machine User Guide, LUMINAR EVERYDAY 59250 2ft LED Linkable Plant Grow Light Owners Manual, Viatom Blood Pressure Monitor BP2 & BP2A User Manual. The scripts will process data from the WiFi and LAN Data . This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. My data logger turned out to be faulty. Yes Screenshot of the Status page in the configuration interface. Solis Plant Offline, Please Check Devices and Netwo. If the connection is weak (1-2 bars) then it is recommended to install a. range extender to boost the signal strength where the logger is going to be. When I am logged into the data logger via wifi the status says that it is connected and when I test the connection on the server page it seems to be all good. What do I do next? Sorry we couldn't be helpful. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China.Tel: +86 (0)574 6578 1806Fax: +86 (0)574 6578 1606Email : info@ginlong.comWeb : www.ginlong.com, solis SOL-DLS-W Data Logger Wifi Stick Introduction Data Logger Wifi Stick Is mainly used: 10 inverters 10 realize, solis GPRS Stick Datalogger Delivery Content 1 GPRS stick 1 GPRS Antenna 1 Quick Installation Manual 1nstall the, BRP069B45 FTX-K (20/25/35), ATX-K (20/25/35), FTXTP-K (25/35), FTXP-K (20/25/35), ATXP-K (20/25/35), ATXTP-K (25/35) FTX-K (20/25/35), ATX-K (20/25/35), FTXTP-K, Your email address will not be published. ), Get the latest developments in Ginlong Solis, Copyright@2019 Ginlong Technologies All Rights Reserved, Solis_datasheet_S3-GPRS,WiFi-ST_IND_V2.0_2022_08.pdf. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection.Solis monitoring system can be monitored remotely by WIFI to provide users accurate and comprehensive data analysis and fault alarm at any time and place,, make product operation . Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Data Logging Stick: S2-WL-ST. Support WiFi and LAN communication / Plug and play, quick installation . This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Did you find it helpful? No-Grid - El inversor no reconoce la red. Reliability Safety Capacity WiFi Data Logger. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. You can select the corresponding server information according to the model of data logger used by the plant. You will have full control of your system whenever and wherever you are. Victor is the author of this solution article. SolisCloud App helps you manage PV plant: 1. Step 3: Confirm the plant information.Click Create a plant.Step 4: Click View plant to enter the plant homepage, then add the datalogger. Insert the datalogger to the inverter COM port. I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? I too have recently tried to connect to the Ginlong data logger without success. Did you get a response from Ginlong? Plug the logger into the inverter - be sure the inverter is on with at least DC power, Open the Wi-Fi settings on your phone and then search for new networks, Look for a network called "Solis_XXXXXXXXXX" the "XXXXXXXX" should be the serial number of the logger, Open a browser on your phone and enter 10.10.100.254 into the address bar, Enter "admin" for the password and "123456789" for the password then hit Log In, Go to Quick Set and then tap Search in the top left corner, Select the local Wi-Fi network that you wish to use, Enter the Wi-Fi network password (be sure that it is correct) and then tap Save, If everything was done correctly, the "Solis_XXXXX" network should disappear and the NET/COM lights on the logger should begin flashing, At this point you can go to SolisCloud and add the data logger to your plant, Use the scanner to scan the QR code sticker on the logger, Place your hand behind the logger if the scanner is not working (this helps it to focus), If you are still not having luck scanning the logger you can enter the serial number manually, Go to the Device tab on your plant and then to the Data Logger tab, The data logger should now be displayed here with note about when it last reported. on Properties, select internet protocol IPv4(TCP/IPv4). Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed; Reset WiFi Stick to Factory Settings This is to (1) ensure you have the correct, password and (2) ensure there is a strong enough. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. Monitoring Accessory Configured But Still Won't Link? Log in to the page , the username is "admin" and the password is also "admin" 5. I will ask AGL for a replacement. SolisCloud is the new generation of intelligent PV system monitoring. Router password is incorrect 3. I have set up an account on Ginlongmonitoring.com and entered the details of the data logger. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. See if this helps you out https://www.youtube.com/watch?v=0F0aGeTOYw8. Let us know how can we improve this article! Go to the web browser and go to 10.10.100.254 and password is admin:admin. If there are symbols in the password, it must be changed or the logger will not connect to it. Thanks, The Boards Team. Thanks for your help, my data logger looks like it is faulty. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Router has a firewall blocking the data, 5. If failed, re-do the configuration process or contact the after-sale engineers. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. 1. However, there is no guarantee that interference will not occur in a particular installation. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . Hi all, The AutoSave Draft feature is now disabled across the site. Technician check pins 3 and 4 for 1.5 - 1.7 VDC, 2. Environmental Issues, Home Automation & Internet of Open theSolisCloudapp on your phone. Your email address will not be published. No, Modified on: Tue, Oct 25, 2022 at 4:55 PM. *, We appreciate your effort and will try to fix the article. Internal DC Short: In the inverter head, or the wirebox? Shows the connection status between the datalogger and the server. Yes S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Dataloggers can be scanned or added manually by entering in the serial number. WiFi datalogger firmware is out of date. Help us improve this article with your feedback. A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. Tap the Plant icon in the bottom left corner of the screen, Tap the plus sign in the top right corner and then tap "Add Plant", Fill in all of the required fields on the "Create Plant" page and then tap "Done" in the top right corner, Tap "Create Plant" to finish making a system inSolisCloud- tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if theWiFidata logger is plugged into the bottom of the inverter, A scanner will automatically come up. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Questions and discussion about solar, batteries, and other renewable energy technology. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s You can rerun the wizard and see if that works. Verify the RSSI (signal strength) is higher than 15%. If you have not already been registered on SolisCloud, please see Step 18: SolisCloud . Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Step 3: Manually fill in the datalogger SN or Scan the SN on the datalogger. ContactPlease contact us if you have any technical problems in terms of the product. :). Connect one end of an ethernet cable to LAN stickand other end directly to a computer. Open the Local Connection Status, clickon Properties, select internet protocol IPv4(TCP/IPv4). Shows the power supply status of the datalogger. 2. View the total data of your PV plant. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Note: the logger is unable to connect to any. Step2: Connect the datalogger to the corresponding 4-pin COM port of the inverter. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . 2023 AGL recognises the Aboriginal and Torres Strait Islander peoples as the Traditional Owners of the lands on which we work, and we acknowledge those communities' continuing connections to their lands, waters and To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Enter the password for the network and then tap "Next". It is highly recommended to first connect your phone to the home network that you wish to connect theWiFilogger to. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This should serve as a reminder to manually save your drafts if you wish to keep them. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. Step1: Open the datalogger shell and install the SIM caret. I haven't been able to log onto it after many attempts. Connect to the inverter (to get power), 3. Victor is the author of this solution article. The communication topology is as shown below: Description of Symbols Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. No-Grid - El inversor no reconoce la red. Model: AP300 Hardware Version: V11. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Open the Local Connection Status, click. Then plug the. This process can also be used to move a Solis Data Logger from one site to another. 2019-08-29 16:17:17. The warranty shall be executed by the terms included here but not limited to PO/Pl/Cl of goods. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Issue was more to do with the router's wifi signal not being strong enough in the attic than the data logger itself. If you hate cookies, or are just on a diet, you can disable them altogether too. Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis Data Logger Server Information - wyjtki w firewall'u, Pylon US2000C/US3000C Battery - CAN Failure - No Battery - Deutsch, Solis Data Logger Server Information - firewall exceptions. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. If you hate cookies, or are just on a diet, you can disable them altogether too. app on your phone. You can select the corresponding server information according to the model of data logger used by the plant. It may also be affected by lighting storms. We have just had a solar system installed. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters.
Sanford School Department Jobs,
When A Guy Says You Taste Good Down There,
Articles S